Clinical Trials

Condition or Disease

  1. A
  2. B
  3. C
  4. D
  5. E
  6. F
  7. G
  8. H
  9. I
  10. J
  11. K
  12. L
  13. M
  14. N
  15. O
  16. P
  17. Q
  18. R
  19. S
  20. T
  21. U
  22. V
  23. W
  24. X
  25. Y
  26. Z

3 studies in Atrial Fibrillation

  1. Catheter Ablation vs Anti-arrhythmic Drug Therapy for Atrial Fibrillation Trial Rochester, MN View Summary

    Catheter Ablation vs Anti-arrhythmic Drug Therapy for Atrial Fibrillation Trial

    Location:

    Rochester, MN

    Trial status:

    Open for Enrollment

    Why is this study being done?

    The need for this trial arises out of 1) the rapidly increasing number of pts > 60 years of age with AF accompanied by symptoms and morbidity, 2) the failure of anti-arrhythmic drug therapy to maintain sinus rhythm and reduce mortality, 3) the rapidly increasing application of radio-frequency catheter ablation without appropriate evidence-based validation, and 4) the expanding impact of AF on health care costs. This study will randomize 3000 patients to a strategy of catheter ablation versus pharmacologic therapy with rate or rhythm control drugs. Each pt will have 1) characteristics similar to AFFIRM pts (≥65 yo or <65 with >1 risk factor for stroke, 2) Documented AF warranting treatment, and 3) Eligibility for both catheter ablation and ≥2 anti-arrhythmic or ≥3 rate control drugs. Pts will be followed every 6 months for >2 yrs and will undergo repeat trans-telephonic monitor, Holter monitor, and CT/MR studies to assess the impact of treatment. The CABANA trial will disclose the role of medical and non-pharmacologic therapies for AF, establish the cost and impact of therapy on quality of life and will help determine if AF is a modifiable risk factor for increased mortality.

    NCT ID:

    NCT00911508

    Who can I contact for additional information about this study?

    Rochester: HRS Research Office 507-255-7456
                        


  2. Pivotal Clinical Study of the CardioFocus Endoscopic Ablation System - Adaptive Contact (EAS-AC) (HeartLight) in Patients With Paroxysmal Atrial Fibrillation (PAF) Jacksonville, FL Rochester, MN View Summary

    Pivotal Clinical Study of the CardioFocus Endoscopic Ablation System - Adaptive Contact (EAS-AC) (HeartLight) in Patients With Paroxysmal Atrial Fibrillation (PAF)

    Location:

    Jacksonville, FL Rochester, MN

    Trial status:

    Open for Enrollment

    Why is this study being done?

    A randomized, controlled trial designed to demonstrate the safety and effectiveness of the experimental device to deliver pulmonary vein isolation as a treatment for symptomatic atrial fibrillation.

    NCT ID:

    NCT01456000

    Who can I contact for additional information about this study?

    Rochester: Kristi Monahan, RN 507-255-6676
                        

    Jacksonville: Barbara Little, RN, BSN 904-953-8361
                        

  3. Use of the Hansen Medical System in Patients With Atrial Fibrillation Rochester, MN View Summary

    Use of the Hansen Medical System in Patients With Atrial Fibrillation

    Location:

    Rochester, MN

    Trial status:

    Open for Enrollment

    Why is this study being done?

    Atrial fibrillation (AF) is the most common sustained cardiac rhythm disturbance, increasing in prevalence with age. AF is often associated with structural heart disease, although a substantial proportion of patients with AF have no detectable heart disease. Hemodynamic impairment and thromboembolic events related to AF result in significant morbidity, mortality, and cost. Catheter ablation therapy is widely recognized as a useful modality for patients with fibrillation that are refractory to medical and ICD treatment, and is increasingly used earlier in treatment. Physicians specializing in Interventional Cardiology (IC) and/or Electrophysiology (EP) are often confronted by the need to precisely place and control a variety of therapeutic and non-therapeutic catheters in the cardiovascular space. A variety of shapeable and steerable sheaths and guide catheters have been developed to meet this need. These manually controlled catheters traditionally rely upon the ability of the experienced physician to apply varying amounts of curvature via pull wires of a steerable catheter. This tip curvature is then used in combination with insertion and torque to manipulate the distal tip of the catheter in a desired fashion. The manual control over the fine movements of the catheter's distal tip typically has limitations for performing complex mapping, ablation and other therapeutic procedures. Maintaining stable tissue contact at the point of ablation is important in achieving efficient heat transfer to tissues without increasing the power requirement, but micro-movement can be difficult to assess. Therefore, stable tissue contact relies on operator skill to exert forces at cardiac tissue that is constantly shifting due to cardio-respiratory movement. Robotic catheter manipulation may be one way to overcome or improve the problem of catheter stability. In minimally invasive surgery, robotic assisted control of the surgical instruments has helped physicians perform difficult dexterous surgical tasks safely and efficaciously. Robotic remote control of catheters has recently been introduced to assist physicians in the safe, accurate placement of the distal catheter tip during percutaneous cardiac procedures. In ablative procedures it is not known whether improving catheter tip stability has a significant effect on lesion quality compared to the manual approach, but some recent publications of both animal and human studies comparing the Hansen Sensei Robotic System and Artisan guide catheter to manual delivery of the ablation catheter suggest that contact pressure conferred by the robotic system results in improved lesion delivery compared to a manual approach and that the use of robotic manipulation during ablation procedures has a event rate similar to manual manipulation. It has been convention to deliver energy for up to sixty seconds for slow pathway modification and accessory pathways to produce irreversible tissue necrosis. One study suggested that by 30 seconds, robotic ablation appears to exceed the manual ablation signal attenuation at 60 seconds. The study confirmed that transmural lesions were produced at 30 seconds of robotic ablation. Therefore, it may be possible to use shorter ablation times or lower power settings for robotic approaches. This may in turn reduce the likelihood of complications for example, the risk of damage to contiguous structures and the risk of steam pop which is most likely to occur after 30s at temperatures greater than 400C. Subjects who satisfy the inclusion and exclusion criteria shall be randomized 2:1 between the robotic arm and the manual control arm of the trial. Those in the manual control arm will receive treatment for their arrhythmia per the investigators standard practice and the labeling for the Navistar ThermoCool. Subjects in the robotic arm will be treated according to the following parameters: - Place ablative lesions 1-2 cm outside of the pulmonary veins in order to minimize the risk of pulmonary vein stenosis. - Target IntelliSense readings of 10-20g, with a maximum of 40g, during lesion creation. - Target lesion creation at RF power settings of 20-25W with a nominal maximum power of 30W. Starting at 20-25W in an anatomical region, RF power may be increased after 15 seconds in 5W increments to achieve a transmural lesion as shown by local atrial electrogram attenuation or splitting. Ablation duration at a single anatomical lesion location is recommended to be no longer than 30 seconds. If ablation output time for the RF generator is set for longer than 30 seconds, the ablation catheter should be moved so that the ablation catheter duration in a particular location doesn't exceed 30 seconds. Remember that stable contact between the catheter tip and the tissue increases the efficiency of RF power transfer to the tissue. - For power levels up to 30W, a flow rate of 17 ml/min should be used. - If the temperature increases to greater than 50°C or the impedance rises 20Ω or more, the RF application should be terminated immediately, the catheter removed and the coagulum removed (if present), and irrigation flow confirmed before the catheter is used again. After the index procedure, subjects will receive follow-up monitoring as follows: 7 Day: A phone call will be made to the subject to inquire regarding any adverse events and to assess any change in NYHA classification since discharge. 30 day: Subjects will be asked to return for a follow-up visit at 30 days. At this follow-up visit, subjects will undergo an evaluation for changes in medications (anti-arrhythmic, anti-platelet or anti-coagulation) and adverse events, and receive a physical examination and 12L EKG. 90 day:Subjects will be asked to return for a follow-up visit at 90 days. At this follow-up visit, subjects will undergo the same evaluation as at 30 days. An event recorder issued to patient at this visit to be used through day 365 (1 year) to document symptomatic recurrence of AF. 180 day: Subjects will be asked to return for a follow-up visit at 180 days. At this follow-up visit, subjects will undergo the same evaluation as at 30 days. In addition a 24 hour Holter monitor recording and a Cardiac CT or MR will be obtained. 365 day: Subjects will be asked to return for a follow-up visit at 365. At this follow-up visit, subjects will undergo the same evaluation as at 30 days. In addition a 24 hour Holter monitor recording and a potentially a Cardiac CT or MR will be obtained.

    NCT ID:

    NCT01122173

    Who can I contact for additional information about this study?

    Rochester: Kelly Wock 507-255-7456
                        


Contact us

Clinical studies questions

Cancer-related clinical studies questions

International patient clinical studies questions